In order to guarantee normal operation of plunger pump, Leo filter press ask every plunger pump users to take down the following items:
a. Please use clean hydraulic oil, please filter hydraulic oil every month and change hydraulic oil every three months
b. Pump should not be stared or work if no cooling water feeding into the pump, in order to prevent ceramic plunger breakage and rubber gasket damage due to overheat or overcool suddenly. Besides ,the cooling water also can be used in ceramic cleaning to prolong plunger and gasket service time
More information for the plunger pump please visit: http://www.leofilterpress.com/filter_press/?311.html